Global Standards for the Microelectronics Industry
Standards & Documents Search
Title![]() |
Document # | Date |
---|---|---|
HERMETICITYStatus: Reaffirmed September 2017 |
JESD22-A109B | Nov 2011 |
Testing for hermeticity on commercial product is not normally done on standard molded devices that are not hermetic. Commercial product that this test method applies to has a construction that produces a hermetic package; examples of this are ceramic and metal packages. Most of these tests are controlled and updated in the military standards, the two standards that apply are MIL-STD-750 for discretes, & MIL-STD-883 for microcircuits. The test within these standards can be used for all package types. Within these standards the tests are similar; MIL-STD-750 Test Method 1071 Hermetic Seal is recommended for any commercial hermetic requirements. For MIL-STD-883 the applicable test method is 1014 Seal. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.1 Free download. Registration or login required. |
||
HANDLING AND INSTALLATION OF POWER SEMICONDUCTORS IN DISC TYPE PACKAGES: Included in JESD282 and EIA397.Status: RescindedJun-92 |
TENTSTD11 | Jan 1973 |
A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-22.2 |
||
Guidelines for Visual Inspection and Control of Flip Chip Type Packages (FCxGA) |
JEP170A | Jun 2024 |
This document provides guidelines for visual inspection and control that ensures quality and reliability of flip chip packaged devices. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINES FOR USER NOTIFICATION OF PRODUCT/PROCESS CHANGES BY SEMICONDUCTOR SUPPLIERS - SUPERSEDED BY JESD46, August 1997.Status: Rescinded |
JEP117 | Apr 1994 |
A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.4 Free download. Registration or login required. |
||
GUIDELINES FOR THE PACKING, HANDLING, AND REPACKING OF MOISTURE-SENSITIVE COMPONENTS - SUPERSEDED BY J-STD-033, May 1999.Status: RescindedNovember 1999 |
JEP124 | Dec 1995 |
A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.4 Free download. Registration or login required. |
||
GUIDELINES FOR THE MEASUREMENT OF THERMAL RESISTANCE OF GaAs FETS: |
JEP110 | Jul 1988 |
This publication is intended for power GaAs FET applications requiring high reliability. An accurate measurement of thermal resistance is extremely important to provide the user with knowledge of the FETs operating temperature so that more accurate life estimates can be made. FET failure mechanisms and failure rates have, in general, an exponential dependence on temperature (which is why temperature-accelerated testing is successful). Because of the exponential relationship of failure rate with temperature, the thermal resistance should be referenced to the hottest part of the FET. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.7 Free download. Registration or login required. |
||
Guidelines for Supplier Performance Rating |
JEP146B | May 2023 |
This publication establishes guidelines and provides examples by which customers can measure their suppliers based on mutually agreed upon objective criteria. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
Guidelines for Reverse Recovery Time and Charge Measurement of SiC MOSFET Version 1.0 |
JEP201 | Aug 2024 |
This guideline is intended to overcome the limitations of prior standards and provide a test circuit and method that provides both reliable and repeatable results. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
Guidelines for Representing Threshold Voltage of SiC MOSFETs in Datasheets, Version 1.0Release Number: Version 1.0 |
JEP202 | Jan 2025 |
This publication provides guidelines for representation of threshold voltage and transfer characteristic of SiC MOS device in datasheets. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
Guidelines for Representing Switching Losses of SIC MOSFETs in Datasheets |
JEP187 | Dec 2021 |
This document describes the impact of measurement and/or setup parameters on switching losses of power semiconductor switches; focusing primarily on SiC MOSFET turn-on losses. In terms of turn-off losses, the behavior of SiC MOSFETs is similar to that of existing silicon based power MOSFETs, and as such are adequately represented in typical datasheets. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-70.2 Free download. Registration or login required. |
||
GUIDELINES FOR REPORTING AND USING ELECTRONIC PACKAGE THERMAL INFORMATION |
JESD51-12.01 | Nov 2012 |
This document provides guidelines for both reporting and using electronic package thermal information generated using JEDEC JESD51 standards. By addressing these two areas, this document can be used as the common basis for discussion between electronic package thermal information suppliers and users. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINES FOR PREPARING CUSTOMER-SUPPLIED BACKGROUND INFORMATION RELATING TO A SEMICONDUCTOR-DEVICE FAILURE ANALYSIS:Status: Reaffirmed January 2025 |
JEP134 | Sep 1998 |
The purpose of this Guideline is to provide a vehicle for acquiring and transmitting the necessary information in a concise, organized, and consistent format. Included in the Guideline is a sample form that facilitates transferring the maximum amount of background data to the failure analyst in a readily interpretable format. Immediate availability of this key information assists that analyst in completing a timely and accurate failure analysis. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.4 Free download. Registration or login required. |
||
Guidelines for Particle Impact Noise Detection (PIND) Testing, Operator Training, and Certification |
JEP114A | May 2023 |
This publication is a guideline to test facilities in their efforts to establish and maintain consistent particle impact noise detection (PIND) testing. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
Guidelines for Packing and Labeling of Integrated Circuits in Unit Container Packing (Tubes, Trays, and Tape and Reel) |
JEP130C | Feb 2023 |
This document establishes guidelines for integrated circuit unit container and the next level (intermediate) container packing and labeling. The guidelines include tube/rail standardization, intermediate packing, date codes, tube labeling, intermediate container and shipping labels, and standardize tube quantities. Future revisions of this document will also include tray and reel guidelines. The objective of this publication is to promote the standardization of practices between manufacturers and distributors resulting in improved efficiency, profitability, and product quality. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINES FOR NONDESTRUCTIVE PULL TESTING OF WIRE BONDS ON HYBRID DEVICESStatus: Rescinded |
JEP96 | Jan 1977 |
A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-13.5 |
||
Guidelines for Measuring the Threshold Voltage (VT) of SiC MOSFETs |
JEP183A | Jan 2023 |
This publication describes the guidelines for VT measurement methods and conditioning prior to VT testing in SiC power MOSFETs to reduce or eliminate the effect of the aforementioned hysteresis. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-70.1 Free download. Registration or login required. |
||
Guidelines for Gate Charge (QG) Test Method for SiC MOSFET |
JEP192 | Jan 2023 |
This publication defines a QGS, TOT, QGD and QGS, TH which can be extracted from a measured QG waveform for SiC MOSFETs. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINES FOR GaAs MMIC PHEMT/MESFET AND HBT RELIABILITY ACCELERATED LIFE TESTING |
JEP118A | Dec 2018 |
These guidelines apply to GaAs Monolithic Microwave Integrated Circuits (MMICs) and their individual component building blocks, such as GaAs Metal-Semiconductor Field Effect Transistors (MESFETs), Pseudomorphic High Electron Mobility Transistors (PHEMTs), Heterojunction Bipolar Transistors (HBTs), resistors, and capacitors. While the procedure described in this document may be applied to other semiconductor technologies, especially those used in RF and microwave frequency analog applications, it is primarily intended for technologies based on GaAs and related III-V material systems (InP, AlGaAs, InGaAs, InGaP, GaN, etc). A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.7 Free download. Registration or login required. |
||
GUIDELINES FOR COMBINING CIE 127-2007 TOTAL FLUX MEASUREMENTS WITH THERMAL MEASUREMENTS OF LEDS WITH EXPOSED COOLING SURFACE |
JESD51-52A | Nov 2022 |
This document is intended to be used in conjunction with the JESD51-50 series of standards, especially with JESD51-51 (Implementation of the Electrical Test Method for the Measurement of Real Thermal Resistance and Impedance of Light-emitting Diodes with Exposed Cooling Surface) document. This present document focuses on the measurement of the total radiant flux of LEDs in combination with the measurement of LEDs's thermal characteristics: guidelines on the implementation of the recommendations of the CIE 127-2007 document are provided. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-15 Free download. Registration or login required. |
||
Guideline to Specify a Transient Off-State Withstand Voltage Robustness Indicator in Datasheets for Lateral GaN Power Conversion Devices, Version 1.0 |
JEP186 | Dec 2021 |
This guideline describes different techniques for specifying a Transient Off-state Withstand Voltage Robustness Indicator in datasheets for lateral GaN power conversion devices. This guideline does not convey preferences for any of the specification types presented, nor does the guideline address formatting of datasheets. This guideline does not indicate nor require that the datasheet parameters are used in production tests, nor specify how the values were obtained. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-70.1 Free download. Registration or login required. |
||
GUIDELINE FOR SWITCHING RELIABILITY EVALUATION PROCEDURES FOR GALLIUM NITRIDE POWER CONVERSION DEVICES |
JEP180.01 | Jan 2021 |
This document is intended for use by GaN product suppliers and related power electronic industries. It provides guidelines for evaluating the switching reliability of GaN power switches and assuring their reliable use in power conversion applications. It is applicable to planar enhancement-mode, depletion-mode, GaN integrated power solutions and cascode GaN power switches. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-70.1 Free download. Registration or login required. |
||
Guideline for Reverse Bias Reliability Evaluation Procedures for Gallium Nitride Power Conversion Devices |
JEP198 | Nov 2023 |
This publication presents guidelines for evaluating the Time Dependent Breakdown (TDB) reliability of GaN power switches. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINE FOR OBTAINING AND ACCEPTING MATERIAL FOR USE IN HYBRID/MCM PRODUCTSStatus: Reaffirmed May 2023 |
JEP142 | May 2023 |
This document provides guidance regarding design considerations, material assessment techniques, and recommendations for material acceptance prior to use in Hybrid/MCM Products. As part of the risk assessment process, both technical requirements and cost should be carefully considered with regard to testing/evaluating the elements of a hybrid microcircuit or Multi-chip Module (MCM) prior to material release for assembly. The intent of this document is to highlight various options that are available to the Hybrid / MCM manufacturer and provide associated guidance, not to impose a specific set of tests. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINE FOR MEASUREMENT OF ELECTRONIC PACKAGE INDUCTANCE AND CAPACITANCE MODEL PARAMETERS: |
JEP123 | Oct 1995 |
The need for this guideline arose from widespread lack of consistency in characterizing electrical parameters of electronic packages, which existed in the industry until the early 1990s. Then, the JEDEC Committee JC-15 provided the forum where various methods were discussed and commonality in approach emerged. The result is that today we have relatively consistent results in measuring and reporting electrical package parameters, as well as specialized tools (e.g., the IPA-510, the interconnect parameter analyzer) which were developed to support the methodology. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINE FOR INTERNAL GAS ANALYSIS FOR MICROELECTRONIC PACKAGESStatus: Reaffirmed November 2020 |
JEP144A | Nov 2011 |
This guideline is applicable to hermetically sealed microelectronic components (including discrete semiconductors, monolithic and hybrid microcircuits). Specific cases with unique packaging, materials, or environmental constraints may not find all of the following information and procedures applicable. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-13 Free download. Registration or login required. |
||
Guideline for Gate Oxide Reliability and Robustness Evaluation Procedures for Silicon Carbide Power MOSFETs |
JEP194 | Feb 2023 |
This document provides guidelines for evaluating gate reliability and lifetime testing for silicon carbide (SiC) based power devices with a gate oxide or gate dielectric. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
Guideline for Evaluating Gate Switching Instability of Silicon Carbide Metal-Oxide-Semiconductor Devices for Power Electronic Conversion |
JEP195 | Feb 2023 |
This document elaborates on the information given in JEP184 regarding the long-time stability of device parameters under static conditions and under application near switching conditions. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
Guideline for Evaluating dv/dt Robustness of SiC Power Devices, Version 1.0 |
JEP190 | Aug 2022 |
This document provides stress procedures, general failure criteria and documentation guidelines such that the dv/dt robustness can be demonstrated, evaluated and documented. This document gives examples for test setups which can be used and the corresponding test conditions. Additionally, criteria are explained under which device manufacturers can select an appropriate test setup. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-70.2 Free download. Registration or login required. |
||
Guideline for Evaluating Bipolar Degradation of Silicon Carbide Power Devices |
JEP197 | Nov 2023 |
This publication provides guidance to SiC product suppliers and related power electronic industries in their evaluation of bipolar degradation mechanism in SiC power devices. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINE FOR DEVELOPING AND DOCUMENTING PACKAGE ELECTRICAL MODELS DERIVED FROM COMPUTATIONAL ANALYSIS: |
JEP126 | May 1996 |
This publication provides a guideline to suppliers of IC components with a template for documenting the numerical simulation assumptions. In addition this guideline also suggests a model environment to reference when comparing various packages or component suppliers. This publication should improve the communication between the package model suppliers. This publication should improve the communication between the package model supplier and the end user. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-15.2 Free download. Registration or login required. |
||
GUIDELINE FOR CONSTANT TEMPERATURE AGING TO CHARACTERIZE ALUMINUM INTERCONNECT METALLIZATIONS FOR STRESS-INDUCED VOIDING:Status: Reaffirmed October 2012, April 2025 |
JEP139 | Dec 2000 |
This document describes a constant temperature (isothermal) aging method for testing aluminum (Al) metallization test structures on microelectronics wafers for susceptibility to stress-induced voiding. This method is valid for metallization/dielectric systems in which the dielectric is deposited onto the metallization at a temperature considerably above the intended use temperature, and above or equal to the deposition temperature of the metal. Although this is a wafer test, it is not a fast (less than 5 minutes per probe) test. It is intended to be used for lifetime prediction and failure analysis, not for production Go-NoGo lot checking. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.2 Free download. Registration or login required. |
||
Guideline for Characterizing Solder Bump Electromigration Under Constant Current and Temperature Stress |
JEP154A | Mar 2024 |
This publication describes a method to test the electromigration susceptibility of solder bumps, including other types of bumps, such as solder capped copper pillars, used in flip-chip packages. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
GUIDELINE FOR ASSESSING THE CURRENT-CARRYING CAPABILITY OF THE LEADS IN A POWER PACKAGE SYSTEM: |
JEP145 | Feb 2003 |
This publication is intended as a guideline to establish procedures, consideration and common practices that will allow a manufacturer, an application entity, a system designer and other interested parties to define current capability limitations in the leads of components and power systems with semiconductor components. This is a guideline, not a standardized method, it was developed over several years to clarify questions that had been posed to committee members in their respective engineering functions. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-25 Free download. Registration or login required. |
||
GUIDE TO STANDARDS AND PUBLICATIONS RELATING TO QUALITY AND RELIABILITY OF ELECTRONIC HARDWARE |
JEP70C | Oct 2013 |
This document gathers and organizes common standards and publications relating to quality processes and methods relating to the solid-state, microelectronics, and associated industries. This is intended to facilitate access to the applicable documents when working with electronic hardware. This will have a positive effect on quality and reliability as users gain more access to proper methods in designing, producing, and testing parts. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.4 Free download. Registration or login required. |
||
GUIDE FOR THE PRODUCTION AND ACQUISITION OF RADIATION-HARDNESS ASSURED MULTICHIP MODULES AND HYBRID MICROCIRCUITS: |
JEP133C | Jan 2010 |
A revised and expanded publication for suppliers and users of radiation hardness assured (RHA) multichip modules (MCMs) and hybrid microcircuits, is now available. The document provides guidance as to how to achieve, maintain and ensure required levels of radiation-hardness given the fact that the constituent dice can have different levels of hardness assurance. It also describes how to deal with the various radiation hardness situations that an MCM/Hybrid developer, procuring activity or user will encounter. The guide is intended to supplement three relevant performance specifications: MIL-PRF-38534, MIL-PRF-38535 and MIL-PRF-19500. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-13.5, JC-13.4 Free download. Registration or login required. |
||
GUIDE FOR STANDARD PROBE PAD SIZES AND LAYOUTS FOR WAFER LEVEL ELECTRICAL TESTING:Status: Rescinded September 2021 (JC-14.2-21-182) |
JEP128 | Nov 1996 |
This guide has been replaced by JESD241: September 2021. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-14.2 |
||
Graphics Double Data Rate 7 SGRAM Standard (GDDR7) |
JESD239B | Feb 2025 |
This standard defines the Graphics Double Data Rate 7 (GDDR7) Synchronous Graphics Random Access Memory (SGRAM) specification, including features, functionality, package, and pin assignments.
A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Free download. Registration or login required. |
||
Graphics Double Data Rate (GDDR6) SGRAM Standard |
JESD250D | May 2023 |
This document defines the Graphics Double Data Rate 6 (GDDR6) Synchronous Graphics Random Access Memory (SGRAM) specification, including features, functionality, package, and pin assignments. The purpose of this Standard is to define the minimum set of requirements for 8 Gb through 16 Gb x16 dual channel GDDR6 SGRAM devices. System designs based on the required aspects of this standard will be supported by all GDDR6 SGRAM vendors providing compatible devices. Some aspects of the GDDR6 standard such as AC timings and capacitance values were not standardized. Some features are optional and therefore may vary among vendors. In all cases, vendor data sheets should be consulted for specifics. This document was created based on some aspects of the GDDR5 Standard (JESD212). A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-42.3C Free download. Registration or login required. |
||
GRAPHICS DOUBLE DATA RATE (GDDR5X) SGRAM STANDARD |
JESD232A.01 | Mar 2023 |
Terminology update. This standard defines the Graphics Double Data This standard defines the GDDR5X SGRAM memory standard, including features, device operation, electrical characteristics, timings, signal pin assignments, and package A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-42.3, JC-42.3C Free download. Registration or login required. |
||
GRAPHICS DOUBLE DATA RATE (GDDR5) SGRAM STANDARDRelease Number: C.01 - Terminology update |
JESD212C.01 | Jan 2023 |
Terminology update. A list of RAND License Assurance/Disclosure Forms is available to JEDEC members on the restricted Members' website. Non-members may obtain individual Assurance/Disclosure forms by requesting them from the JEDEC office. Committee(s): JC-42.3C Free download. Registration or login required. |